An apparatus with 318x 430x43(HxWxD) physical dimensions in mm scale which are used for amplifying the signals transmitted to long distance in DWDM optical networks. Amplifiers are produced in different Inlines, Booster and PReAmp models. Booster is used for amplifying the signal power in the source station, Inline in the mid-route and PreAmp is used in the Destination. This system functions in AGC and APC modes.
An In/Out adaptor
Alarm LED (consisting of Pump, out, PWR, Ptem, ma, In, Run and Tem)
The REST switch equivalent to Reset
The Eth and Console ports
The PS-B, FAN, RS-A and ERR lights
In the rear view: There are two Power switches, two Connectors and two Fuses.
parameter | Min | Typ | Max | Units |
Operating wavelength | 1528 | 1561 | nm | |
Input optical power range | -15 |
| 4 | dBm |
Input optical power threshold | -20 | - | - | dBm |
output power | -3 | 16 | dBm | |
On/off gain | 12 | dB | ||
Gain flatness |
| 1.5 | - | dB |
Noise factor | - | 5.5 | 0.3 | dB |
Operating voltage | AC220V & DC-48V | v | ||
interface | LC-UPC | |||
Working temarotene | -5 | - | +60 | centigrade |
Storage temperature | -40 | - | +80 | centigrade |
Humidity | 5 | - | 85 | % |
Power supply | 85/170 | 110/220 | 132/264 | VAC |
Size(H*D*W) | 430x320x43.6 | mm |
Item | Description |
PS_A | Powe Supply A normal, green is on. |
PS_B | Powe Supply B normal, green is on |
FAN | Fan LED, ON is normal |
ERR | While error, red is on |
RUN | System operating normally, green is on |
IN | When the input optical power is below the set threshold input power, red is on. |
OUT | When the output optical power output power lower than the set threshold, red is on |
PUMP | Pump laser is abnormal, red is on |
mA | Pump current warning LED Indicators, when pump current is abnormal, red is on. |
Ptem | Pump temperature warning LED Indicators, when the pump temperature is too high, red is on |
Tem | Equipment temperature warning LED Indicators, when the device temperature is too high, red is on |
Interface Printing | Name | Function |
RJ45 | Ethernet Port | Remote Management Interface |
Consul | Serial port | Serial Management Interface |
In | Input | EDFA Input Interface |
Out | Output | EDFA Output Interface |
P_In | PA Input Interface |
|
P_Out | PA Input Interface |
|
MON | Monitoring Port |
|
Type and gain of amplifier | Part number |
Preamp, gain:20 | DMAEDFPA016020 |
Preamp, gain:25 | DMAEDFPA016025 |
Preamp, gain:30 | DMAEDFPA016030 |
Preamp double, gain:28 | DMAED2PA020028 |
Booster, gain:12 | DMAEDFBA016012 |
Booster double, gain:14 | DMAED2BA022014 |
Inline, gain:12 | DMAEDFLA016012 |
Inline double, gain:12 | DMAED2LA022024 |
Doble Preamp and Booster | DMAEBP22201428 |
Preamp and Inline | DMAEPL20222824 |
Booster and Inline | DMAEBL22221424 |
Technical Data Sheet Technical Data Sheet Popular | 03/08/1400 20:21:14 48.57 KB | |